Easy Automotive Modules
Evaluation Kit EASYKIT AUX DRIVES (FS50R07W1E3_B11A)
Quick Start Guide
Application Note 11 AN2012-10
Evaluation Kit EASYKIT AUX DRIVES (FS50R07W1E3_B11A)
2.3.1 Power Board Connector Description
For Pin1 location please see Figure 6.
+15V gate driver supply (required for power board only operation)
Digital Ground (required for power board only operation)
PWM Input for Low-Side IGBT Phase U
PWM Input for High-Side IGBT Phase U
PWM Input for Low-Side IGBT Phase V
PWM Input for High-Side IGBT Phase V
PWM Input for Low-Side IGBT Phase W
PWM Input for High-Side IGBT Phase W
HighSide gate driver fault event hiding. Required to start bootstrap supply. Function
is continuous on for power board only operation – no signal required.
Not RESET input from the uC. (connect to +5V_HV Pin 6 for power board only
operation)
Not FAULT output signal to the uC
+5V analog supply. (is connected to +5V_HV – Pin6 for power board only operation
– no supply required)
+5V analog supply. (is connected to +5V_HV – Pin6 for power board only operation
– no supply required)
Analog 0..5V output signal of phase U voltage
Analog 0..5V output signal of NTC temperature
Analog 0..5V output signal of phase V voltage
Analog 0..5V output signal of low side phase U current (ratiometric output)
Analog 0..5V output signal of phase W voltage
Analog 0..5V output signal of low side phase V current (ratiometric output)
Analog 0..5V output signal of DCL-voltage
Analog 0..5V output signal of low side phase W current (ratiometric output)
Analog Ground (is connected to GND_DIG – Pin2 for power board only operation –
no supply required)
Analog Ground (is connected to GND_DIG – Pin2 for power board only operation –
no supply required)
Analog Ground (is connected to GND_DIG – Pin2 for power board only operation –
no supply required)
Minimum required signals for power board only tests have indicated with bold font.